The multiprocessing issue

The rest of this page assumes you know how native ComfyUI manages memory. If you don't, read this page first.

ComfyUI manages RAM and VRAM to optimize for speed and stability on all kinds of hardware, also making use of comfy-aimdo for paging.

  • streams weights per layer when a model does not fit
  • holds back a reserve for work it cannot size in advance
  • pins host RAM so transfers are fast
  • runs paging through comfy-aimdo
  • caches what every node produced so a re-run skips the work.
  • ...

It is good code, well tested and runs on all operating systems and hardware ranging from a 2011 laptop to an H100 server.

Unfortunately it currently assumes that there is ever only exactly one process, which creates a few problems for us.

We have tried to maintain as much of the native memory management as possible through several strategies, without doing any patching or using any unmaintanable or unclean tricks.

ComfyUI memory management that survives comfy-env

Every memory optimization and function ComfyUI uses and whether it reaches a worker today.

# Mechanism Today ELI5
1 load_models_gpu admission yes What ComfyUI does. load_models_gpu is what every loader node calls:
  • adds up what the incoming models need: size plus 10 percent, plus the larger of 0.8 GiB and the model's own activation estimate, plus the reserve
  • calls free_memory for that much
  • then loads
Under isolation. The one input comfy-env has to keep honest is free VRAM:
  • Linux: device wide, so what workers hold is already counted
  • Windows: the calling process's own budget, so comfy-env publishes what workers hold into the reserve term
A worker about to load runs the same sum through the host, which frees room on its behalf. See admission and the reserve.
2 free_memory eviction ladder yes What ComfyUI does. free_memory is asked for a number of bytes of VRAM on one device and makes them free:
  • walks current_loaded_models, sorted: the model already most offloaded first, then the least referenced, then the smallest
  • unloads one at a time, re-reading free VRAM after each
  • stops when the request is covered or the list runs out; a model it never listed is never asked
Under isolation. The stand-in comfy-env registers for every model a worker holds is in that list, so a worker's model is asked in its turn and the worker does the real unload. See the stand-in model.
3 The reserve (EXTRA_RESERVED_VRAM, --reserve-vram) yes VRAM ComfyUI keeps untouched for work it cannot size in advance. comfy-env forwards the same reserve to every worker and to the pager, and raises it only where the host cannot see workers. See admission and the reserve.
4 Admission, the activation guess no The admission sum is only as good as its parts, and one part is a guess ComfyUI hardcodes. For a controlnet, the "how much scratch memory will this need while running" term returns zero, while in reality the control image is kept on the card at full pixel resolution for the whole run. Worse, a ControlLora builds a whole second network on the card without going through admission at all, so a model appears that nothing registered and nothing can evict. None of this is comfy-env's doing: the host under books by exactly the same amount as a worker would, because the number comes from upstream and comfy-env never computes it. The consequence under isolation is the same as native, a load admitted with less room than it really needs; it is listed here so nobody expects comfy-env to have fixed it. See admission and the reserve.
5 get_free_memory yes "How much room is left", read the same way by both sides. The stand-in's size never enters it. See admission and the reserve.
6 Free memory as a batch sizer no Free VRAM is not only used to decide whether a model fits; samplers and the VAE also divide it by an estimate to decide how many images to process at once, several times per step, and that decides gigabytes of activations. The number they divide is "free VRAM plus everything the pager could still evict from this process". That second term is strictly local: a worker cannot know what the host could evict, and the host cannot know what a worker could. So on Linux each side sees what the other holds and shrinks its batches for it, but neither ever grows because the other could make room, which is slower than native, never unsafe. Two of upstream's own sizers make it worse regardless of comfy-env: one reads the raw free figure and under batches any paged model, and the tiled VAE fallback reads total VRAM rather than free and grows its tile until the estimate fits, so two processes each grow into most of the same card. Nothing on the process boundary can fix a decision made inside a sampler loop. See what only upstream can fix.
7 Dtype chosen from the size of the whole card no When a model is loaded, ComfyUI decides whether to keep its weights small (fp8) or upcast them to fp16, and that decision is worth twice the whole weight set. It decides by comparing the model's size with 88 percent of the card's total memory, not with what is free. So nothing a sibling process holds enters the decision and no reserve can shrink it: a host and a worker on one 48 GB card, each loading a 12B fp8 checkpoint, each conclude there is room and each upcast, 48 GB of weights before a single activation. On a 24 GB card they both correctly decide there is no room, by luck of the arithmetic. This is the inverse of row 6: there both sides shrink for each other, here both grow. The gates fire in the default configuration, pager or not, and they run inside the loader where the process boundary has no say. Both sides pick exactly what native would have picked; the trouble is that native never had a sibling. See what only upstream can fix.
8 cgroup RAM accounting no Inside a Docker container the machine may have 256 GB of RAM while the container is allowed 32 GB. Since 2026-08-27 ComfyUI reads the container's limit and sizes everything RAM related against it: how much RAM it may pin for fast transfers, when the results cache must start evicting, the Windows swap gate. comfy-env's own readings still come from psutil, which reports the whole machine, so inside a container the host and comfy-env are sizing against two different numbers. And the deeper problem has no fix from either side yet: the host and every worker live in the same container and share the one budget, but each process independently sizes its pin ceiling and its cache headroom against the full budget, as if it were alone. Five processes each believing they may pin 2 GB less than 32 GB is not a 32 GB budget. See what only upstream can fix.
9 unload_all_models and the Free button yes The button reaches the stand-in and the worker releases everything. See the stand-in model.
10 Cast buffers partial Per process scratch VRAM for the layer being copied. Every process pays for its own; comfy-env books the incoming load's share in the reserve, but they are never shared. See inside a worker.
11 Partial load budget (lowvram_model_memory) no "Load only this much of the model" never reaches a worker: the stand-in is not a partially loadable model on either path. See inside a worker.
12 LoadedModel size questions partial How big is it, how much is on the card. The stand-in answers from what the worker measured; some reads assume internals the stand-in only fakes. See the stand-in model.
13 aimdo headroom yes The pager's own reserve. comfy-env forwards it at runtime as the published reserve changes. See admission and the reserve.
14 Model compiler, malloc graph and CUDA graphs no A sibling process faulting during another's CUDA graph capture is uncoordinated. The sharpest edge in this table. See what only upstream can fix.
15 The inactive cache tier yes Results cached in RAM and drained at every node. Worker results sit in the host's cache like any other entry. See inside a worker.
16 Per-layer fault and aimdo's C-side eviction yes The pager pages each process's weights by the pressure it senses itself. Works, with no coordination possible from Python. See inside a worker.
17 model_unload, partial versus full yes The stand-in implements partial unload and returns the bytes actually moved, so ComfyUI's arithmetic stays right. See the stand-in model.
18 OOM branch in execution.py yes A worker's out of memory error crosses as the real torch class, so ComfyUI's top level handling runs as native. See inside a worker.
19 The OOM retry ladder no Eleven sites retry smaller on OOM, each shrinking its own process. A worker retries alone and the host never learns the pressure came from it. See what only upstream can fix.
20 The activation estimate yes A per model constant, read as native, now sizing the reserve on two processes instead of one. See admission and the reserve.
21 /free partial The unload half reaches the stand-in. The cache reset half is host only, which is right, since worker results live in the host cache. See what only upstream can fix.
22 cleanup_models prune yes Dead entries are pruned; the stand-in carries the weakref the prune expects. See the stand-in model.
23 Async offload streams yes The stream count is mirrored to workers and read live when booking cast buffers. See inside a worker.
24 cudaMallocAsync as the default allocator yes Mirrored. It is also why a GPU tensor crossing the boundary is copied rather than shared (see zero-copy CUDA transfer). See inside a worker.
25 Prompt boundary signals yes The prompt id is read; upstream merged the provider and comfy-env registers none. See what only upstream can fix.
26 model_load and the finalizer tripwire yes The stand-in is inserted into the list directly and satisfies what the finalizer checks. See the stand-in model.
27 Dirty mmap bounce yes Mirrored. Two workers loading the same file share the page cache instead of each copying it. See inside a worker.
28 Entry identity and the dead-entry sweep partial The effect is right, the visibility is not: comfy-env must hold the stand-in's patcher strongly or the sweep drops it. See the stand-in model.
29 Clone dedup and is_clone yes Upstream probes the incoming host model with the stand-in as the argument, and the stand-in answers not a clone, which is the case that matters. Two of the three read paths assume internals. See the stand-in model.
30 is_dynamic gate and the per-node ledger walk yes The stand-in answers False and nothing deeper is read; the worker's own pager handles its models. See the stand-in model.
31 Hook weight caching no A memory counter taken once per process and spent against a card two processes share. Nothing declares it, nothing reclaims it. See what only upstream can fix.
32 The unpatch backup dict no Per process CPU copies of patched weights. Host RAM the pin ladder never sees. See what only upstream can fix.
33 Multigpu deepclones no comfy-env is single device throughout. See what only upstream can fix.
34 Pin eviction ladder no Worker pinned RAM is invisible to the host's pin ladder. See what only upstream can fix.
35 --disable-smart-memory yes The flag is read, and the prompt end unload_all_models reaches the stand-in. See inside a worker.
36 Node output cache and RAM-pressure release yes Worker outputs are host cache entries and are released like any other, upstream's own tie breaking bug included. See inside a worker.
37 Allocator cache release (soft_empty_cache) partial Runs in the host only when something was actually unloaded. The worker's allocator cache is released by the idle sweep instead. See inside a worker.
38 loaded_models() leak into node code yes Stand-ins register with currently_used False, so a node that calls loaded_models() does not pick them up. See the stand-in model.
39 Interrupt flag partial Forwarded at progress callbacks only, and read rather than consumed. See exceptions. See what only upstream can fix.
40 unload_model_and_clones yes The stand-in's clone id is a private sentinel that never matches a real uuid. See the stand-in model.
41 GET /system_stats partial On Linux vram_free is device wide and right. On Windows it excludes what workers hold. See what only upstream can fix.
42 MAX_PINNED_MEMORY and hostbuf ceilings partial Mirrored, and it binds by default on one path out of six. See inside a worker.

Three things fall out of the table.

  • The stand-in is the mechanism, not an option. Row 2 is reachable only because a fake model for each worker model sits in ComfyUI's list. Without it the host can decline to take memory it does not have, which is useful, but it cannot take memory back, which is the half that matters when the card is already full.
  • The risk is narrower than the mechanism. Three rows carry a broke exposure on the stand-in page: 29 (clone dedup), 30 (the is_dynamic gate and the per node pin walk) and 38 (the loaded_models() leak into node code). Everything else comfy-env does is reading values and publishing one number.
  • Only upstream can fix rows 14 (the model compiler and CUDA graph capture), 19 (the OOM retry ladder), 33 (multigpu deepclones) and 39 (the interrupt flag). Nothing has been proposed for any of them. The counterexample runs the other way: row 25, the cache provider, is already merged upstream and comfy-env simply does not register one.
Twenty-three more behaviours already work inside a worker and need no bridge

These are per process by nature. A worker runs the same manager on the same tree, so it already gets them right for its own models. Listed so the reader can see what a bridge does not have to carry.

# Behaviour ELI5 Why it already works in a worker
1 ModelPatcher.clone A second remote control for the same TV, not a second TV A MODEL never crosses the boundary in either direction (ADR-0040), so the host never clones a worker model
2 LoRA patching, baked or applied per forward Stickers on the weights Entirely inside the process that owns the module
3 Legacy load, partial load, partial unload, unpatch Put as much on the card as fits, move layers back when told The worker runs the real code on its own models
4 ModelPatcherDynamic.load and per-layer paging Reserve the seats, walk people in only when called Each process owns its vbars and its aimdo context
5 aimdo's own accounting (get_total_vram_usage, loaded_size) The pager's own scoreboard, the only one right for a paged model The worker reads its own context and publishes one scalar
6 Pinned RAM registration Lock the weights' RAM pages so the card can pull them fast The worker pins into its own ledger and its own hostbufs
7 ensure_pin_budget against machine-wide available RAM Before locking more RAM, check the whole machine still has 2 GB spare One machine-wide number, read independently by each process with no coordination. The floors differ, though (row 34): the host's is max(RAM_CACHE_HEADROOM / 2, 2 GiB) with the headroom set by its executor per prompt, while a worker runs no executor, so its headroom stays 0 and its floor is exactly 2 GiB
8 set_ram_cache_release_state Before locking RAM, ask the results cache to make space first Per process; a worker can set its own headroom without touching the host
9 Model files through the page cache (load_safetensors, safe_open) Point at the file instead of copying it; two programs pointing at one file share one copy The kernel shares pristine pages across processes under both mappings
10 read_tensor_file_slice_into Read the layer straight from the file into the fast lane Per process
11 Cast buffers and their per-node reset Scratch space on the card for the layer being copied, wiped after every step The worker runs its own reset at its node boundary
12 PromptModelTracker marks A sticky note "in use by this job" so the RAM bouncer picks someone else first The worker reads the prompt id at its call boundary and marks its own models
13 Dtype decisions (should_use_fp16, unet_dtype) Whether a model is stored at full, half or quarter size All dtype flags are mirrored as resolved values
14 vram_state (--lowvram, --highvram, ...) The big dial for how aggressively models stay on the card Crosses per call on the budget request; the three vram flags are deliberately not mirrored
15 Placement (unet_offload_device, vae_device, ...) Where each kind of model is born and parked Per process, and Linux free memory already sees worker VRAM
16 get_total_memory How big the card is Each process reads the same card
17 aimdo enable and pressure flags Whether paging is on and how it senses pressure Exported to workers as env vars; the worker follows the host's resolved state
18 Stream, pinning, mmap and allocator flags How many lanes copy weights, whether RAM is locked, which allocator is used Mirrored as resolved values; cudaMallocAsync is inherited through the environment by default, unless the pack's [env_vars] sets its own PYTORCH_CUDA_ALLOC_CONF
19 Cache type flags (--cache-ram, --cache-none, ...) How much the host remembers between runs Executor side; workers run no queue
20 OOM recognition and retry smaller (VAE tiling, attention halving) Recognise "out of memory" and retry at a smaller size Runs on the worker's own allocator, which is the right process
21 Interrupt checks inside node loops Long loops peek at the Cancel flag The code runs unchanged on the worker's own flag; the host never sets it (see row 39 above)
22 set_cudnn_benchmark after node import Undo plugins that turned on a memory-hungry speed setting The worker sets its own policy at import
23 hook_breaker save and restore ComfyUI repeatedly undoes a specific kind of plugin tampering Not a worker behaviour; listed because a planted list entry is data rather than a patched function, so it is immune, while a wrap is not

Process management.

An upstream interface would remove need for ducktyping but not the need for worker-specific logic, because each worker keeps some RAM for its interpreter and torch, and some VRAM for its CUDA context, a fixed cost per process that no model ledger describes.

Where to go next